| Unit box length: | 0.495 |
| Summary: | Eaton 9E 2000I. UPS topology: Double-conversion (Online), Output power capacity: 2 kVA, Output power: 1600 W. AC outlet types: C13 coupler, C19 coupler, Power plug: C13 coupler, AC outlets quantity: 6 AC outlet(s). Typical backup time at full load: 4 min, Typical backup time at half load: 12 min. Form factor: Tower, Product colour: Black. Certification: IEC/EN 62040 -2, CE, CB report (TUV) |
| Efficiency: | 91 |
| Unit box height: | 0.46 |
| Units per shipping box: | 1 |
| Unit box width: | 0.33 |
| Unit calculated volume: | 0.07514 |
| Input frequency: | 50/60 |
| Unit calculated weight: | 23.1 |
| Input operation voltage (max): | 300 |
| Input operation voltage (min): | 100 |
| Noise level: | 40 |
| Output frequency: | 50/60 |
| Output operation voltage (max): | 240 |
| Output operation voltage (min): | 208 |
| Output power: | 1600 |
| Output power capacity: | 2 |
| Ups topology: | Double-conversion (Online) |
| Ac outlet types: | C13 coupler/C19 coupler |
| Ac outlets quantity: | 6 |
| Power plug: | C13 coupler |
| Rs-232 ports: | 1 |
| Serial interface: | Jā |
| Serial interface type: | RS-232 |
| Vendor homepage: | https://powerquality.eaton.com/Products-services/Backup-Power-UPS/9E-1-3kVA.aspx?cx=41&GUID=482418BF-1164-410A-AEB9-A0ED9FA7A642 |
| Description: | The Eaton 9E UPS constantly monitors power conditions and regulates voltage and frequency thanks to the double conversion topology. Eaton 9E UPS can power more servers than most similar UPS because of a 0.8 power factor. - Get clear information on the UPS’ status and measurements (load level, battery level, input/output voltage and frequency) on a single screen with the new LCD interface
- Easily communicate with the UPS through USB, RS232 serial or over the network with the optional network card (Network-MS). Relay cards or Modbus cards are also available
- Integrate 9E into all software environments. The Eaton 9E is delivered with Eaton’s Intelligent Power™ Software and is compatible with all major OS including advanced integration in VMware vCenter and Microsoft Hyper-V
- Wide input voltage range will minimize the battery usage and help to extend battery lifetime
- The internal bypass allows service continuity in case of an internal fault
- Extend runtime
|
| Typical backup time at full load: | 4 |
| Typical backup time at half load: | 12 |
| Form factor: | Tower |
| Product colour: | Black |
| Operating temperature (t-t): | 0 - 40 |
| Certification: | IEC/EN 62040 -2, CE, CB report (TUV) |
| Safety: | IEC/EN 62040-1 |
| Depth: | 190 |
| Height: | 399 |
| Weight: | 22400 |
| Width: | 330 |
| Serial ports quantity: | 1 |
| Usb port: | Jā |